Symptoms We Resolve

COMMON ENCODER FAULTS

  • LOSS OF OUTPUT SIGNAL

    A failed encoder, power supply fault, damaged cable, or broken connection can eliminate position or speed feedback.
  • INTERMITTENT POSITION FEEDBACK

    Vibration, damaged conductors, loose couplings, or electrical noise can result in unstable encoder signals.
  • INCORRECT DIRECTION FEEDBACK

    Channel wiring or configuration issues can cause the controller to interpret movement in the wrong direction.
  • PLC OR DRIVE INPUT FAULTS

    A healthy encoder signal may not be correctly received by the PLC, motion controller, or drive.
  • DAMAGED FLEXIBLE CABLES

    Continuous movement can fatigue encoder cabling, particularly on CNC and automated machinery.
  • INCORRECT REPLACEMENT CONFIGURATION

    Pulse count, voltage, output type, shaft style, and electrical interface all need to match the application.
The Lectro Advantage

WHY CHOOSE LECTRO POWER SYSTEMS?

  • SIGNAL-PATH DIAGNOSTICS

    We trace feedback from the encoder through to the controller or drive.
  • MACHINE CONTROL EXPERIENCE

    We understand how encoder feedback interacts with speed, position, and automated sequences.
  • REPLACEMENT ASSESSMENT

    We can help identify suitable replacement devices where the original encoder is obsolete.
FAQs

Frequently Asked Questions

What happens when an encoder fails?
Can you replace obsolete encoders?
Can you diagnose encoder cabling?